Download Mikado Model Helicopters USB Devices Driver



KOSMIK 170/210/250/300 HV & HV-I

  1. Download Mikado Model Helicopters USB Devices Driver
  2. Download Mikado Model Helicopters Usb Devices Driver Updater
  3. Download Mikado Model Helicopters Usb Devices Driver Download
  4. Download Mikado Model Helicopters Usb Devices Drivers
  5. Download Mikado Model Helicopters Usb Devices Driver Windows 7

Driver download Latest drivers for the VBar USB connection Click on the icon/image at the right side to recieve the download link by mail. You most be logged in with your Mikado ID to use this function. So, downloaded some software to program a gyro in a model helicopter. The download went fine, and as far as I can tell drivers are in too and running, but the pc won't talk to the gyro. According to device manager the gyro is plugged into Com4. I have seven USB ports on my new machine but they seem to be numbered from 4 upwards. MIKADO Model Helicopters GmbH. 40 DE 14469 Potsdam +49 331 23749-0 +49 331 23749-11: info@mikado-heli.de: www.mikado-heli.de. Shop system & ERP. Garmin Support Center United Kingdom is where you will find answers to frequently asked questions and resources to help with all of your Garmin products.

In version 1.10 the telemetry functions for the KOSMIK 170/210/250/300 HV & HV-I have been extended. The data exchange is now also supported by

  • PowerBox
  • FrSky
  • Futaba CGY 760
  • JETI CentralBOX

There are some special features to be considered with this software update.

When downloading the software update, the virus scanner may report a virus . The software has been checked by KONTRONIK and is definitely virus-free, the virus message can therefore be ignored. KONTRONIK will try to find a solution as soon as possible.

To avoid errors and malfunctions during the update process the update procedure must be carried out as described below:

First a bootloader update to software version 1.0 must be performed. Version 1.0 will overwrite the existing firmware of the KOSMIK and does not contain any further functions!

With the following steps the Bootloader-Update, Version 1.0 is installed on the KOSMIK 170/210/250/300 HV & HV-I:

1. install the Bootloader-Update, Version 1.0 with the ProgUnit.

ATTENTION: When starting the update, an error message is displayed that the software is older than the software available on the KOSMIK. Please confirm this error message with 'Yes' and the update will start.

Helicopters

Download Mikado Model Helicopters USB Devices Driver

Download Mikado Model Helicopters USB Devices Driver

2. after finishing the update, disconnect the battery.

3. IMPORTANT: Connect motor and receiver.

4. connect the battery again.

5. wait until the controller beeps. The beep confirms that the bootloader update has been successfully installed.

Now that the bootloader is updated, the new firmware version 1.10 must be installed on the KOSMIK.

KOSMIK 160/200 - Version 4.17

  • Optimization and revision of Graupner telemetry protocol
  • Adapted overcurrent warning of motor current at Graupner

_____________________________________________________________________________

PRIOR SOFTWARE VERSIONS:

COOL KOSMIK 250/300 HV - Version 1.2.

  • Motor current warning with Graupner telemetry adapted

KOSMIK 160/200 - Version 4.15 as well as KOSMIK 250/300 - Version 1.1

The new software allows to use the updated Data Explorer to read out the data from the SD card.

Download mikado model helicopters usb devices drivers

KOSMIK 160/200 - Version 4.14

  • Capacity measurement has been optimized
  • Mode 7 (reversal of rotation direction) was added
  • JETI protocol has been adapted (now also compatible with R-EX, REX and REX-Assist receivers)
  • Futaba protocol adapted (now also compatible with Futaba CGY760R)
  • KONTRONIK protocol was changed CRC check adapted

Version 4.13

  • Bugfix: Graupner HoTT telemetry - capacity limit warning when Bluetooth module is plugged in

Version 4.12

  • Includes a new KONTRONIK protocol for telemetry.

Version 4.10

  • Supports the use of TelMe JETI and MIKADO.

Version 4.9

  • supports the use of the TelMe Futaba for the FX 22, T18MZ, T18MZ-WC and T14SG. It also allows operation with HV-LiPos with a charging voltage of up to 4.35 V.

Version 4.8

  • supports the use of the new TelMe-Futaba.

Version 4.6

  • With the current K-Konfig interface, we can offer you new programming options, such as entering the values for your alarms. The restart time after bailout has been shortened depending on the set ramp-up time to ensure a timely restart even with long ramp-up times. The calculation of the withdrawn capacity has been optimized. To be able to use the parameters, the new K-Config interface is mandatory. If ProgDISC is used, an update must also be carried out for this.

Version 4.5.1

  • Elimination of the problem with writing log files to Micro SD cards.

If your KOSMIK does not work after the update, please proceed as follows:

1. reset the controller

2. install the current software again

If your KOSMIK still does not work after this, you will unfortunately have to send it in for repair. Please do not forget to enclose our service form.

JIVE Pro 80+ HV / JIVE Pro 120+ HV

Version 1.14

  • Mode 7 (Reverse rotation) has been added
  • JETI protocol has been adapted (now also compatible with R-EX, REX and REX -Assist receivers)
  • Futaba Protocol adapted (now also compatible with Futaba CGY760R)
  • KONTRONIK protocol was changed: CRC-Check adjusted

_____________________________________________________________________________

PRIOR SOFTWARE VERSIONS:

Version 1.13

  • Bugfix: Graupner HoTT telemetry - Capacity Alarm with connected bluetooth module

Version 1.12

  • offers an KONTRONIK protocol for telemetry

Version 1.10

  • TelMe JETI und MIKADO can be used

Version 1.9

  • TelMe Futaba FX 22, T18MZ, T18MZ-WC and T14SG can be used.

Version 1.8

  • supports the use of the new TelMe-Futaba.

Version 1.6

  • the alarm parameters of the new K-Config interface are programmable. Additionally, the automatic pre-commutation has been optimized to reduce the extreme current peaks occuring in some engines. To use the parameters the new K - Config surface is imperative. When using the PROGDISC an update must be carried out for those as well

KOLIBRI 60/90/140 LV & LV-I

Version 2.1

With the update of the software to version 2.1, the telemetry port and the Bluetooth function of the KOLIBRI LV-I can now be used simultaneously.

With the previous software version, the Bluetooth function could only be used when the telemetry cable was disconnected. This improvement is especially important for the KOLIBRI 140 LV-I, as it has two telemetry ports.

IMPORTANT: If version 2.0 has already been installed on the KOLIBRI LV-I controller, this is a normal update and can be carried out as described in the instructions.

If an older software version than version 2.0 has been installed, the update must be installed on the controller as a bootloader update. The procedure for the bootloader update is described in detail for version 2.0 or also in the instructions under Point 8.Update, Number 12.

KOLIBRI 90/140 HV-I

Version 1.2

USB

In version 1.2 a parameter for peak current control was integrated to improve the performance of the controller.

The telemetry functions have also been extended. With the software function 1.2 the data exchange is possible with

  • PowerBox
  • FrSky

There are some special features to be considered with this software update.

When downloading the software update, the virus scanner may report a virus. The software has been checked by KONTRONIK and is definitely virus-free, so the virus message can be ignored. KONTRONIK will try to find a solution as soon as possible.

To avoid errors and malfunctions during the update process the update procedure must be carried out as described below:

Attention: For steps 1, 3 and 5 please make sure that the battery voltage is applied without interruption, otherwise the bootloader may be damaged and it is necessary to send the controller to KONTRONIK!

1. update the firmware as usual with ProgUNIT

Download Mikado Model Helicopters USB Devices Driver

2. after finishing the update, disconnect the drive battery and reconnect it.

3. program mode 1.

4. disconnect actuator battery and reconnect it. Wait until the controller initializes.

5. press and hold button until the controller beeps (this can take several seconds). The beep of the bootloader update is different from the mode programming beep, so it is clearly visible.

6. disconnect and reconnect the drive battery, the controller initializes and is now ready for user defined settings.

For all users who do not use a ProgUnit and still want to use the update, we offer to install the update free of charge at KONTRONIK's factory. Please send the controller together with the KONTRONIK service form to the address given.

___________________________________________

PRIOR SOFTWARE VERSIONS

Version 2.0

By updating the software, we have integrated two new parameters for dynamic current control and peak current control into the boot loader to further improve the performance of the controller.

The telemetry functions have also been expanded. With the software function 2.0 the data exchange with Futaba CGY760 and JETI CentralBOX has been improved. Furthermore, the telemetry function can now also be used with the systems

  • PowerBox
  • FrSky

There are some special features to be considered for this software update.

When downloading the software update, the virus scanner may report a virus. The software has been checked by KONTRONIK and is definitely virus-free, the virus message can therefore be ignored. KONTRONIK will try to find a solution as soon as possible.

To avoid errors and malfunctions during the update process the update procedure must be carried out as described below:

Attention: For steps 1, 3 and 5 please make sure that the battery voltage is applied without interruption, otherwise the bootloader may be damaged and it is necessary to send the controller to KONTRONIK!

1. update the firmware as usual with ProgUNIT

2. after finishing the update, disconnect the drive battery and reconnect it.

3. program mode 1.

4. disconnect actuator battery and reconnect it. Wait until the controller initializes.

5. press and hold button until the controller beeps (this can take several seconds). The beep of the bootloader update is different from the mode programming beep, so it is clearly visible.

6. disconnect and reconnect the drive battery, the controller initializes and is now ready for user defined settings.

For all users who do not use a ProgUnit and still want to use the update, we offer to install the update free of charge at KONTRONIK's factory. Please send the controller together with the KONTRONIK service form to the address given.

_______________________________________________________________

Version 1.4

Until now, the KOLIBRI LV-I controllers have output a voltage of 9V until initialisation. This is no problem for all receivers and FBL systems known to us. However, if pilots still use 6V servos, we have found that in the worst case they could be damaged.

With version V1.4 we have now programmed our software in such a way that the KOLIBRI LV-I controllers no longer start with a voltage peak, but also enter the BEC voltage regulation before initialisation. The BEC voltage set by the user is thus output by the KOLIBRI LV-I controller throughout, even before initialisation.

This means that the minimum BEC voltage now also corresponds to the voltage that actually occurred in flight.

With this software update there are a few special features to consider, therefore the update procedure should be carried out as described below: Attention: In steps 1, 3 and 5 please make sure that the battery voltage is available without interruption, otherwise the bootloader may be damaged and the controller has to be sent to KONTRONIK!

1. Update the firmware, as usual with ProgUNIT or ProgDISC. Setting the parameters is only possible with the ProgUNIT.

2. After the update is complete, disconnect the drive battery and reconnect it.

3. Program mode 1.

4. Disconnect and reconnect the drive battery. Wait until the controller initializes.

5. Press and hold the button until the controller beeps (this can take several seconds).

The bootloader update beep is different from the mode programming beep, so it is clearly visible.

6. disconnect and reconnect the drive battery, the controller initializes and is now ready for custom settings.

Version 1.3

  • Graupner motor current warning has been optimized
  • Capacitance measurement has been optimized

Live-cell therapy for KOBY

ProgUNIT

Actual software Version for ProgUNIT. Important: Please do not use the PROGDISC-software for ProgUNIT or vice versa!

PROGDISC

With this update the PROGDISC is optimized for the latest generation of our KOBY series.

For print media please use the eps file (free scalable without loss of quality):

For all screen applications please use the png file (NOT scalable)

We will be pleased to send you our logo according to your requirements (length x width, file format). Please write us a short message.


Current KONTRONIK price list in EUR (price list in USD) and spare parts price list as well as our order form


Nothing suitable found? Please use our drive calculation service.


Archives:


Archives:


Archives:

Download Mikado Model Helicopters Usb Devices Driver Updater

Archiv:

Here you find the DataExplorer (Version 3.3.8), a software to visualize SD-card data.

Download Mikado Model Helicopters Usb Devices Driver Download

PC-Software (Windows ™) for ProgUNIT and PROGDISC

Download Mikado Model Helicopters Usb Devices Drivers

  • K-KONFIG V1.3.9(compatibility for Windows versions from Windows 7 onwards)
  • Manual (explains all parameters and its values)

Download Mikado Model Helicopters Usb Devices Driver Windows 7

  • Apple Windows 10 Boot
    Camp 6 Driver Bundlex64 driver
  • Microsoft USB Input
    Device Driver
    10.0.10240.16384 for
    Windows 10x64 driver
  • Asus Support Device
    Driver 10.0.0.13 for
    Windows 10 Anniversary
    Update 64-bitx64 driver
  • Microsoft WDF
    KinectSensor Interface 0
    Driver 2.2.1610.17001
    for Windows 10
    Anniversary Update
    64-bitx64 driver
  • Icom OPC-1122U USB
    Driver 1.5x64 driver
  • Icom OPC-966U USB Driver
    1.5x64 driver
  • Yokogawa AQ7260 USB
    Driver 1.0.3.9x64 driver
  • ASUS Wireless Radio
    Control Driver 1.0.0.7
    for Windows 10
    Anniversary Update
    64-bitx64 driver
  • Gemalto IDBridge CT30
    USB Driver 4.1.3.0
    64-bitx64 driver
  • Huawei GNSS Sensor
    Driver 1.1.24.0 for
    Windows 10 64-bitx64 driver
  • Asus Support Device
    Driver 10.0.0.10 for
    Windows 10 64-bitx64 driver
  • Lenovo ACPI-Compliant
    Virtual Power Controller
    Driver 15.10.28.170 for
    Windows 10 Anniversary
    Update 64-bitx64 driver
  • Render ACPI Device
    Driver 15.58.20.163 for
    Windows 10 64-bitx64 driver
  • Gemalto Sentinel USB Key
    Driver 7.54.0.0 64-bitx64 driver
  • Huawei GNSS Sensor
    Driver 1.1.28.0 for
    Windows 10x64 driver